How to Clean Fiber Connectors
Dirty connectors are one of the most common causes of fiber trouble, and cleaning them is one of the easiest fixes. A single-mode core is about 9 microns wide. A typical speck of dust is bigger than that, so one speck can block the light, cause high loss, or get ground into the end face and wreck the connector for good.
The good news: cleaning takes about ten seconds once you know the routine. The bad news: "it's brand new, it's fine" isn't part of that routine. New cords and dust caps can be dirty too.
What you need
- Fiber inspection scope or probe. This is the only way to know a connector is clean. Guessing doesn't count.
- One-click cleaners sized to your connectors (1.25 mm for LC, 2.5 mm for SC/ST/FC, plus an MPO version if you work with MPO). They clean both patch cord ends and connectors sitting inside adapters.
- Cleaning cassette or lint-free fiber wipes for dry cleaning.
- Fiber cleaning fluid or 99% isopropyl alcohol for stubborn grime. Not the 70% stuff from the medicine cabinet, because the water leaves residue.
- Clean dust caps to put back on afterward.
Step by step: inspect, clean, inspect
- Make sure the link is dark. Never look into a fiber end, a port or a scope that might be connected to live equipment. Laser light can be invisible and still damage your eyes.
- Inspect first. Put the end face under the scope. If it's clean, plug it in and you're done.
- Dry clean. Use a one-click cleaner or wipe the end face once across a fresh spot on a cassette or lint-free wipe. One pass, one direction, no scrubbing.
- Inspect again. Most dirt comes off with a dry clean.
- Still dirty? Wet-to-dry clean. Put a little fiber cleaning fluid or 99% IPA on the wipe, touch the end face to the damp spot, then drag it straight onto a dry area. That way the solvent lifts the grime and doesn't leave a film behind.
- Inspect one more time. If you see pits, scratches or chips that won't clean off, replace the connector or cord.
- Clean the other side too. The port or adapter it plugs into needs cleaning as well. A clean cord in a dirty port just picks the dirt back up.
- Connect right away, or put a clean cap on.
Never do these
- Never blow on it. Your breath is mostly moisture and enthusiasm.
- Skip the canned air. It can spit propellant residue onto the end face.
- Don't touch the end face. Skin oil is a great cleaner for nothing at all.
- Don't use your shirt, a paper towel or a cotton swab. Each one leaves lint behind.
- Don't reuse a wipe spot. You'll just smear yesterday's dirt around.
- Don't assume caps keep things clean. Dust caps can carry debris of their own. Inspect anyway.
Shop the gear
- Fiber cleaning supplies: one-click cleaners, cassettes, wipes and fluid
- Fiber test equipment: inspection scopes and testers
- Fiber visual fault locators: for finding the break when cleaning isn't the problem
- Fiber tool kits: everything in one case
- SM fiber patch cords and LC-LC patch cords in stock: for when a connector is past saving
New Tech Industries has been helping installers keep their links clean and working since 1982. Not sure which cleaner fits your connectors? Give us a call.