Units will have some exterior wear as they are used.
|
Dynatel 965
Subscriber Loop Analyzer
The Dynatel 965 subscriber
loop analyzer performs all the tests needed to
analyze and troubleshoot the subscriber loop, as
well as cable plant in a single, portable unit. In
addition, the 965 uses combinations of its test
measurements in automatic functions called DC Line
Test and AC Line Test, which interpret results and
lead the operator toward possible solutions to
complex cable problems.
Specifications
- Measures opens 0-100k
feet
- Counts loads up 0-5
- Voltage: 0-250 VAC,
0-350 VDC, current 0-110 mA DC
- Resistance 0-100 Mega
ohms ohms
- Noise metallic 10-50
dBrnC
- Noise to ground
40-100 dBrnC
- Frequency counter
20-20000 Hz
- Ground resistance
0-500 ohms
- Loop and CO
resistance 0-5k ohms
- Resistance fault
locate 0-30 Mega ohms
- Temperature sensor
0°-140°F
- Noise immunity 7 Vac
, Precision tones 404, 1004, 2804 Hz Tracing
tone 577.5 Hz, Harmonic distortion <45 dB (up to
10th harmonic), Variable source 50 Hz to 10 kHz,
operates on 5 C cell alkaline or rechargeable
NiCd batteries. Typical battery life No
backlight 40 hrs NiCd -120 hrs alkaline, With
backlight 12 hrs NiCd- 35 hrs alkaline, Size H x
W x D 7.0 x 10.5 x 7.5 , 5 ft cord, Net weight
lbs.7.5, Operating temperature 0° to 140°F ,
Relative humidity 0-100% condensing, Operating
altitude 0-15,000 ft.
|